Major components: frame w/cover 1; switching assembly 1; contact and arc rupturing assembly 1; usage design: used as frame for circuit breaker; mtg configuraiton: four 7/16 in.Dia holes on 9-3/4 in.By 3 in.Mtg centers;
No other part numbers with same form, fit, and function found.
Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height
Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height
3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts
3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts
3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts
1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts
NSN 5930-01-500-6734
NSN 6620-00-816-9755
NSN 5975-00-627-2509
NSN 5905-00-872-8900
NSN 6620-01-557-6512
NSN 5855-01-369-4192
NSN 6320-00-036-3688
NSN 6110-01-349-8112
NSN 5960-01-593-1936
NSN 5985-00-270-4509
NSN 2925-00-672-5836
NSN 6645-01-222-5468
Last Updated: 05/05/2024